49
RS PRO T&M Selection Guide
Buy this and more at rspro.com
ENVIRONMENTAL
RS-8852 SOUND LEVEL METER WITH DATALOGGER
RS-660 NOISE DOSIMETER
This Noise Dose Meter measures the frequency
weighted noise exposures and peaks sound levels
simultaeously.
MODEL
RS-8852
Maximum Sound Level
30 => 130 (Auto) dB, 80 => 130
(Hi) dB
Minimum Sound Level
30 => 80 (Low) dB, 50 => 100
(Med) dB
Resolution
0.1 dB
Accuracy Class
IEC 61672-1:2002 Class 2
Weighting
A, C
Display Type
LCD
Frequency Range
31.5 Hz to 8kHz
Operating Temperature Range
0°C to +40°C
MODEL
RS-660
Sound Level Range
70dB to 140dB
Resolution
1 dB
Accuracy Class
ANSI S1.25, IEC 61252
Weighting
A, C, Type 2, Z
Display Type
LCD
Battery Type
Li Polymer
Interface Type
USB
Operating Temperature Range
0°C to +50°C
RS-8852
193-8698
RS-660 NOISE DOSIMETER
174-9559
SOUND & VIBRATION MEASUREMENT
This high-quality sound level meter allows for easy
environmental noise measurement for noise and quality
management. The built-in datalogger allows easy transfer
and analysis of data at a later stage by using a USB cable
and conforms to IEC61672-1 Class 2 standards.
The frequency weighting from A to C helps manage sound
levels for the human ear even when working in high decibel
or frequency environments and it is suitable for use on a
wide range of noise measuring applications.
• The large easy-to-read, backlit LCD display makes it easy
to read the results, even when the meter is being used
in poorly lit areas
• Analogue output for connection to chart recorders,
graphic recorders and other data logging systems for
added versatility
• Battery-powered or external 9V DC input
• 30-hour battery life with auto-power off function after
15 mins of idle time
• Weight 350g approximately, including battery, making it
a perfect lightweight and portable unit
• Supplied with instruction manual, battery, screwdriver,
Ø3.5mm earphone plug, software and USB cable for
data transfer
• 4 Sets link Charging
• Multiple simulated dosimeters (termed D1, D2 & D3)
• Simple operation, including direct read-out of results
• Ten built–in standard dose measurement setups:
• OSHA-80, OSHA-90, MSHA-80, MSHA-90, DOD, ACGIH,
ISO-85, ISO-90, NR-15 and NHO-01
• Pause function
• Nine user defined measurement setups
• 30 dose (DATA) result stores
• Download of setups from PC to the meter
• Keypad lock protects meter against accidental operation
• Timers support pre–selection of measurement time and
duration
• USB PC interface for the charging unit
Buy this and more at ro.rsdelivers.com
Click on photo/CODE